A Landlord Gas Safety Record Has Already Been Sent: How Do You Put a Correction Right? (2026)

Classify a challenged landlord gas safety record, obtain the right authorisation and track which recipients need the correction or follow-up.

Gas engineer and office colleague comparing two separate paper report bundles at a desk.

Ask the issuing engineer to verify the disputed address or finding against the visit evidence. Link any authorised correction to the issued copy. If the corrected copy hasn’t reached someone, check the delivery record and arrange an accessible resend. Keep the record of later remedial work with the original gas safety check.

“The address is wrong” can mean the house number is wrong, the landlord’s address is missing, or the PDF actually belongs to the flat upstairs. The first thing to open is the attachment from the sent message. You want the PDF the landlord, agent or tenant actually saw, alongside the job sheet and the engineer’s notes.

From there, the office can find out whether it’s dealing with a paperwork error, a question about the inspection, a later repair or a copy that never reached someone. The gas safety duties below apply to rented homes in Great Britain. The personal data guidance is UK-wide.

Published

Check which address is wrong on the gas safety record

Read the disputed field back to the caller. HSE lists the checked property’s address and the landlord’s or appropriate agent’s name and address as separate entries. The premises address tells you where the appliances and flues are installed. The other entry tells you who the landlord or appropriate agent is. If the agent’s details are missing, confirm with the landlord or agent whose details belong on the record and verify the address they give you.

A mismatch in the premises address needs the engineer’s input, even if it looks like a typo. Put the issued record alongside the job address, access instructions and appliance or flue details recorded on site. Ask the engineer to confirm the premises and equipment checked. A booking shows where the engineer was due to go. The visit evidence helps establish where the check took place.

What you findWho checks itWhat to do next
Missing or wrong landlord or agent detailsThe office verifies the details with the landlord or agent and takes them back to the issuer.Record the verified details and ask the issuer to approve the change to the record.
Wrong flat, house number or postcode on the issued copyThe issuing engineer checks the visit evidence against the address and equipment on the report.If the correct premises were checked, ask the issuer to make the evidenced correction. If another property was checked, tell the landlord so they can arrange the required check at the intended property.
The right PDF is on file but the wrong PDF went outThe sender checks the attachment and recipient against the job.Arrange secure delivery of the right PDF. Refer any disclosure of someone else’s personal data through your breach process.

If a caller says their personal details are inaccurate, log the request and route it to whoever is responsible for the data. A call can count as a request for rectification. The ICO says to take reasonable steps to check the information and consider the evidence the person gives you. Check the date as well as the spelling or address. Details that were correct on the day may still belong in the historical record even after a move. Update the live contact details as appropriate and make clear which address applies to which date.

Send a disputed finding back to the issuing engineer

If someone disputes a defect, a reading, the check date or which appliance was inspected, get the exact line they’re questioning. Send it to the engineer with the issued PDF, the job notes and any relevant photos or test records. HSE says landlord gas safety checks must be done by a Gas Safe registered engineer who is competent for the work. Give the engineer the evidence and time to assess the finding. Pass any immediate safety concern straight to the qualified engineer and the landlord so they can act while the paperwork is reviewed.

The useful reply from the engineer says what the evidence shows. The original finding may stand. The engineer may establish that a result was transcribed incorrectly and approve a correction. If the visit evidence leaves the position unclear, the engineer can advise on further investigation or a visit. Record the reason and who made the decision. If you’re the tenant and the visit date on the report looks wrong, give the landlord or agent the report reference and date. Explain what you dispute and ask them to get the issuing engineer to check the visit evidence. If the evidence can’t establish that the required check took place, ask the landlord to arrange a check with a suitably qualified Gas Safe registered engineer.

When the issuer approves a correction, file the original copy securely with the reason for the change, the approval and the corrected copy. Mark the original as superseded for day-to-day use and record the date the corrected copy was issued separately from the actual check date. If the finding stands, record the reason and tell the person who raised the issue. Keep any outstanding safety work on its own job or task.

Keep the later repair with the original check record

A defect found at the annual gas safety check belongs on that day’s record. HSE says to issue the record when the required checks are complete, even if faults need attention. The landlord must arrange remedial action and ensure an unsafe appliance stays out of use. Supply the original check record to the tenant on the usual timetable under regulation 36. A repair booking is a separate matter.

When the engineer returns, ask for the relevant record of the work and any checks they carried out. File it against the property and the original report reference, with the return visit date. HSE advises supplementing the check record with evidence of follow-up action. The two documents let the landlord see what the engineer found on the first visit and what happened on the second. Ask the engineer what technical documentation the work calls for.

Read the follow-up before closing the job. A note that a part was ordered leaves an action open. An invoice marked paid tells you the money arrived. The engineer’s record explains which work took place and whether there is still an action for the landlord or engineer. Keep a name and next date against any outstanding work, and give the landlord or agent the follow-up they need for the property file and any communication with the tenant.

Hands aligning two separate report bundles inside an open navy job folder beside a closed pen and face-down tablet.

Get the correct copy to each intended recipient

Start with the original send record. Check who was meant to get the PDF, who actually got it, and whether your office or the landlord or agent handles tenant copies. When the issuer has approved a correction, send it by the agreed route to the people who should use it. Say which report and check date it relates to, which earlier copy it supersedes, and what has changed. If you’re sending a repair record, say that it goes with the original check and give the repair date.

For a standard tenancy, regulation 36 requires the landlord to give existing tenants a copy of the check record within 28 days of the check and new tenants a copy of the latest record before they occupy. If you’re sorting out an incorrect copy while that deadline is approaching or has passed, flag it to the landlord promptly. Work from the original check date when you review the delivery history.

HSE allows electronic copies when the tenant is happy with the route and can access the document. A tenant who asks for paper must get a paper copy. An engineer can send the electronic record to the tenant with the landlord’s agreement. If the agent is forwarding it, agree who will follow up with the tenant and ask the agent to confirm what they sent.

Log the copy or reference sent to each recipient, the date and the outcome you can see. A bounced message, a link the tenant can’t open and an envelope awaiting collection each need a named person to check what happened and arrange a workable route. If the controller corrects personal data it previously disclosed, the ICO says to notify recipients unless that is impossible or involves disproportionate effort. If the original went to the wrong person and exposed personal data, use your personal data breach procedure alongside arranging the correct delivery.

Before marking the correction complete, open the new attachment from the send record and check it against the job. A colleague should be able to see which version is current and whether anyone still needs a copy.

Find the issued gas safety report in Checker

Checker keeps landlord gas safety reports alongside the property, customer and job. The landlord gas safety report tutorial shows where you give the file a reference, link it to a booked job, check the finished PDF and send it. When a customer rings about the wrong address, start with that reference and compare the saved report with the PDF they were sent.

Decide where your office will record the engineer’s decision, keep the issued copy and log a corrected send. Run through it with a colleague who wasn’t on the original job. Give them the property and the report reference and ask them to find the PDF that went out, the decision and the file the landlord should use now. For first-time delivery, see how to send a gas safety record and keep proof.

Frequently asked questions

Can the office correct a gas safety record after it has been sent?

The office can check the disputed details and coordinate the correction. Ask the issuer to authorise the change and refer questions about the premises checked or the findings to the issuing engineer. Keep the issued copy linked to any authorised corrected version.

Does later remedial work replace the original findings?

Keep the findings on the original check record. HSE advises keeping the later work record with it, so the landlord can see what was found and what was done on the return visit.

Does a disputed finding have to be deleted?

Ask the issuing engineer to review the evidence and give a reasoned decision. Keep the challenge with the original record and any authorised correction. If the request also concerns inaccurate personal data, route that part through your data protection procedure.

Does a sent correction prove everyone has received it?

Check which copy was supplied and what happened to it. If it bounced, can’t be opened or is still uncollected, agree an accessible route and resend the authorised copy. Record what the recipient received where you can confirm it, and use the original check date to review the landlord’s supply deadline.

Authoritative sources

About Daniel Sedgwick

Daniel Sedgwick is the founder and managing director of Checker, and a former gas engineer. He writes practical guides for trade businesses comparing field workflows, paperwork and commercial admin.

Keep the decision with the job

Create a landlord gas safety report from a job and see how your team can find it again.

Get Started Free

Recent Posts

EICR App With No Signal: What It Must Save on Site So the Report Is Finished Before You Leave (UK, 2026)

An EICR app is only ready for a cellar if every circuit result, observation code, photo and signature stays on the device as you enter it. Here is what it must save, and a flight-mode test to run before you buy.

Read More

Leaving Joblogic as a Small Electrical Contractor: How to Keep Your EICR History, Open Remedials and Retest Dates (UK, 2026)